Pub. MI05-101iom.2
Model MI05-101 Merge/Isolate Cabinet Page: 20 of 24
\\86h27g1-fs\iomdocs\opnotes -- released\mi05-00x merge-isolate cabs\mi05-101.dir\mi05-101iom2.doc
01/09
Using the 12584-001 AMI I/O Expansion Module
If using the Model 12584-001 I/O Expansion Module with the AMI for additional alarm inputs, the input
screen for each input 940 must be programmed.
1. First, program the input Switch Type and the Current Message to be activated by the input.
2. Next, program the Current Output Combination to Output 1. This will cause output 1 to activate
while the input is active. The M/I cabinet will merge all zones during the alarm message as a result
of the active output.
Inputs 940 are independent of the Master Station and will be automatically broadcast to all zones of the
system. The following screen is an example of Input 9. Remaining inputs 1040 must be programmed in
the same fashion if used.